Trinity Cleantech's inverter duty transformers are purpose-built for applications where the load is generated or controlled by power electronics - solar PV inverters, variable frequency drives (VFDs), and industrial converter installations. Designed with reinforced insulation, low eddy current losses in windings, and de-rated core flux to continuously handle the high harmonic content produced by inverters. Each unit is manufactured and tested at our 20+ acre facility in Jadcherla, Telangana.
Windings and core designed for continuous operation under harmonic-rich inverter output without derating or accelerated ageing
Transposed and continuously-wound EC copper conductors minimise eddy current heating under non-sinusoidal waveforms from VFDs and solar inverters
Thermally upgraded insulation rated for the higher thermal stress of harmonic loading - extended insulation life under continuous inverter duty
Certified green transformers with biodegradable ester oil options for solar plants requiring eco-compliant and fire-safe installations
Every component is selected, inspected, and assembled to exacting standards - delivering transformers that outlast and outperform industry benchmarks.
Prime-grade Cold Rolled Grain Oriented silicon steel laminations - cut and stacked with precision to minimise magnetic losses and reduce heat generation under load.
Electrolytic-grade (EC) copper conductors wound in continuous disc / helical / layer configurations depending on voltage and rating - insulated with thermally upgraded paper or Nomex.
High-quality transformer mineral oil or biodegradable synthetic ester oil - providing both electrical insulation and heat transfer. Tested to IEC 60296 / IEC 61099.
Pressed or fabricated steel tank with corrugated fins, pressed steel radiators, or tube-type cooling - designed for ONAN and ONAF operations with bolt-on or welded construction.
From utility-scale solar farms to industrial VFD installations - Trinity inverter duty transformers serve every application where power electronics generate harmonic-rich loads that standard transformers cannot continuously handle.
An inverter duty transformer is specifically designed to operate continuously with the non-sinusoidal, harmonic-rich output of power electronic inverters - without the accelerated heating, insulation degradation, and derating that would affect a standard distribution transformer.
The solar inverter or VFD drive output - containing fundamental frequency plus high-order harmonics from PWM switching - enters the transformer primary winding, which is wound with transposed conductors to minimise eddy current losses at each harmonic frequency.
The CRGO silicon steel core is operated at reduced flux density compared to a standard transformer - this de-rating provides headroom to absorb harmonic flux components without driving the core into saturation or excessive heating.
The secondary winding delivers the required voltage at the output terminals - stepping up for grid injection from a solar plant or stepping down to match drive input requirements. Reinforced insulation handles the higher voltage stress from harmonic waveform peaks.
Mineral or ester oil circulates around the core and windings - critical for inverter duty transformers where harmonic losses generate additional heat beyond what standard load loss calculations predict. Cooling is sized for the actual harmonic-inclusive thermal load.
Solar PV inverter output at 415V (LV) enters transformer primary for step-up to grid injection voltage
Transformer steps up to 11 kV for transmission through the solar plant collector cable network to the substation
Aggregated solar farm output injected at 33 kV into the regional transmission grid via the collector substation
Share your inverter type (solar, VFD, converter), rated capacity, harmonic spectrum or K-factor, voltage class, and site conditions - our engineers will configure the exact inverter duty transformer you need.
#9-1-83 & 84, Amarchand Sharma Complex,
Sarojini Devi Road, Secunderabad,
Telangana, India - 500003
Plot No. L19-L28, TSSIC Green Industrial Park,
Jadcherla, Mahbubnagar District,
Telangana, India —
509302
Common questions about Trinity Cleantech inverter duty transformers, ratings, and specifications.
An inverter duty transformer is a power transformer specifically designed to operate continuously with the non-sinusoidal, harmonic-rich output of power electronic inverters - such as solar PV inverters, variable frequency drives (VFDs), and industrial converters. Unlike standard distribution transformers, inverter duty transformers use transposed copper conductors to minimise eddy current losses, de-rated core flux density for harmonic headroom, and reinforced insulation systems to handle the higher thermal stress of harmonic loading without derating or premature failure.
A standard distribution transformer is designed for sinusoidal loads at power frequency. An inverter duty transformer is designed for non-sinusoidal harmonic-rich loads from power electronics. Key differences: transposed winding conductors to reduce eddy current losses at harmonic frequencies; de-rated core flux density to handle harmonic flux without saturation; reinforced insulation for higher thermal and voltage stress; and cooling sized for actual harmonic-inclusive losses rather than standard load loss calculations alone.
Trinity Cleantech manufactures inverter duty transformers from 100 kVA up to 2500 kVA as standard, with higher ratings available on request. Voltage class is up to 33 kV. Both OCTC and OLTC tapping options are available. Contact our engineering team with your inverter rating, harmonic spectrum, and voltage requirements for a custom configuration.
Yes. Trinity Cleantech inverter duty transformers are suitable for solar PV power plants - designed to handle the harmonic output of solar string and central inverters, rapid generation cycling from cloud transients, and the thermal cycling of daily solar generation profiles. Biodegradable ester oil options are available for solar plants requiring eco-compliant and fire-safe transformer installations.
Trinity Cleantech inverter duty transformers comply with IS:2026, IEC:60076, IS:1180, BS, and SANS as applicable. The company holds BIS certification, ISO 9001:2015, ISO 14001:2015, and ISO 45001 certifications. All units are 100% factory-tested at the Jadcherla, Telangana facility before dispatch.
All inverter duty transformers are designed, wound, assembled, and tested at Trinity Cleantech's 20+ acre manufacturing facility at Plot No. L19-L28, TSSIC Green Industrial Park, Jadcherla, Mahbubnagar District, Telangana - approximately 80 km from Hyderabad. The facility features automated production and in-house testing laboratories.
Fill in your details and our team will respond within 1 business day.
Thank you for reaching out. Our team will review your requirements and get back to you within 1 business day.